HID Proximity - Readers
| Overview | Key Features | Specifications |
The hazardous Location MiniProx provides the same features and dimensions as the MiniProx reader, with an incorporated junction box rated for use in hazardous locations. The junction box is attached to an appropriate surface location utilizing four holes. |
|
|
|
|
Typical maximum* read range ProxCard® II card - up to 5.5" (14 cm) ISOProx® II card - up to 5" (12.5 cm) ProxKey™ II keyfob - up to 2" (5 cm) ProxCard® Plus card - up to 2" (5 cm) SmartProx™ II card - up to 5" (12.5 cm) *Depending on local installation conditions. Dimensions 6.0" x 1.7" x 1.0" (15.2 x 4.3 x 2.54 cm) Material Polycarbonate UL 94 Power supply Standard MiniProx: 5.1-16 VDC Haz. Loc. MiniProx: 5.1-16 VDC Linear power supplies are recommended. Current requirements Average: 40 mA (5 VDC); 50 mA (12 VDC) Peak: 60 mA (5 VDC); 120 mA (12 VDC) Operating temperature -22° to 150° F (-30° to 65° C) Operating humidity 0-95% relative humidity non-condensing Weight With terminal strip 3.5 oz. (99 gm) With pigtail 3.8 oz. (108 gm) Haz. Loc. MiniProx: 3.8 oz. (108 gm) Transmit frequency 125 kHz Excite frequency 125 kHz Certifications Canada/UL 294 Listed: Access Control System Units Canada/UL 1604 Listed (with Haz. Loc. junction box only): Hazardous Locations Class I, Div. 2, Groups A,B,C,D. FCC Certification, United States Canada Certification CE Mark, Europe UK Type Approval Germany Type Approval Australia C-Tick Mark New Zealand EMC Cable distance Wiegand interface: 500 feet (150 m) Clock-and-data interface: 50 feet (15 m) Recommended cable is ALPHA 1295 (22 AWG) 5 conductor minimum stranded with overall shield or equivalent. Additional conductors may be required for LED or beeper control. |
|