Typical mMximum Read Range* ProxCard® II card - up to 5.5" (14 cm) ISOProx® II card - up to 5" (12.5 cm) DuoProx® II card - up to 5" (12.5 cm) ProxKey® II keyfob - up to 2" (5 cm) MicroProx® Tag - up to 2.5" (6.2 cm) ProxCard® Plus card - up to 1.5" (3.7 cm) Smart ISO/DuoProx® cards - up to 2.5" (6.2 cm) Proximity & MIFARE® card - up to 5" (12.5 cm)
*Depending on local installation conditions.
Dimensions 3.15" x 3.15" x 0.80" (8.0 x 8.0 x 2.0 cm) Screw slots provided for 52-60mm hole spacing
Power Supply 5-16 VDC Linear power supplies are recommended.
Cable Distance Wiegand interface: 500 feet (150 m) Clock-and-data interface: 50 feet (15 m) Recommended cable is ALPHA 1295 (22 AWG) 5 conductor minimum stranded with overall shield or equivalent. Additional conductors may be required for LED or beeper control.
Current Requirements Average: 30 mA (5 VDC); 20 mA (12 VDC) Peak: 110 mA (5 VDC); 115 mA (12 VDC)
Operating Temperature -22° to 150° F (-30° to 65° C)
Operating Humidity 0-95% relative humidity non-condensing
Weight 2.2 oz. (63 gm)
Certifications CE Mark Australia C-Tick, New Zealand EU and CB Scheme Electrical Safety (EN60950 and IEC60950 ITE Electrical Safety) Fifteen EU Countries under the R&TTE Directive (EN 300 330 - SRD, and ETS 300 683 - EMC) Canada/UL 294 Listed Canada Certification FCC Certification, United States
|