Specifications

HID's ProxPro II proximity reader for access control combines performance, reliability, and ease of installation into a two-piece, weatherproof potted enclosure. International users will appreciate the multilingual installation manual, lower voltage requirement and flexible mounting options.

  • Ideal for medium-range applications.
  • Available with Wiegand or Clock-and-Data interface.
  • Optional glass mount kit available for mounting the reader behind glass.
  • Potted reader suitable for indoor or outdoor use.
  • Available in black, white, gray or beige.
  • 18" (45 cm) wire pigtail standard; consult factory for 9' (2.7 m) pigtail available by special order.

Key Features:

  • Two-piece reader design allows for easy installation.
  • Available with a Wiegand or Clock-and-Data interface.
  • Provides high reliability, consistent read range and low power consumption.
  • Features include multicolor LED and internal control or host control of the LED and beeper.
  • Mounts directly on metal with minimal impact on the read range performance. Optional kit enables mounting behind glass.
  • Compare features of the ProxPro II to the original ProxPro reader

Typical Maximum Read Range:

  • ProxCard® II Card - up to 9" (22 cm)
  • ISOProx® II Card - up to 8" (20 cm)
  • DuoProx® II Card - up to 8" (20 cm)
  • Smart ISOProx® Card - up to 8" (20 cm)
  • Smart DuoProx® Card - up to 8" (20 cm)
  • HID Proximity and MIFARE® card - up to 8" (20 cm)
  • ProxCard® Plus Card - up to 4" (10 cm)
  • ProxKey® II Keyfob - up to 4" (10 cm)
  • MicroProx® Tag - up to 4" (11 cm)

*Depending on local installation conditions.

Dimensions
5.00" x 5.00" x 1.00" (12.7 x 12.7 x 2.54 cm)

Power supply:

  • 5-16 VDC
  • Linear power supplies are recommended.

Cable Distance:

  • Wiegand interface: 500 feet (150 m)
  • Clock-and-Data interface: 50 feet (15 m)
  • Recommended cable is ALPHA 1295 (22 AWG) 5 conductor minimum stranded with overall shield or equivalent. Additional conductors may be required for LED or beeper control.

Current Requirements:

  • Average: 25 mA at 12 VDC
  • Peak: 125 mA at 12 VDC

Operating Temperature
-22º to 150º F (-30º to 65º C)

Operating Humidity
0-95% relative humidity non-condensing

Weight
13.6 oz. (385 g)

Certifications:

  • Canada/UL 294 Listed
  • FCC Certification, United States
  • Canada Certification
  • CE Mark
  • EU and CB Scheme Electrical Safety (EN60950 and IEC60950 ITE Electrical Safety)
  • Fifteen EU Countries under the R&TTE Directive (EN300 330 - SRD, and ETS 300 683 - EMC)
  • Australia C-Tick (pending)
  • New Zealand (pending)
  • Taiwan (pending)