Products

HID® VertX™ V200 Input Monitor Interface

Alarm input processing for up to 16 zones
VertX V200 Input Monitor Interface
Overview
Specifications

The HID VertX products provide a complete and fully featured hardware/firmware infrastructure for access control software host systems.

The V200 input monitor interface connects up to 16 supervised input circuits. Each input point monitors and reports normal, off-normal, and alarm states. The V200 features on-board flash memory, allowing program updates to be downloaded through the network. The V200 connects to the V1000 via a high speed RS-485 network. The V1000, in turn, communicates with the system host via industry standard TCP/IP protocol, over 10/100 Mbps Ethernet, or the Internet. This architecture minimizes the impact on corporate LANs, by using only one TCP/IP address for every 32 interfaces, and by handling low-level transactions on the RS-485 network.

Key Benefits:

  • Reports supervised or un-supervised alarm circuits.
  • Off-normal condition programmable for each input point (NO or NC alarm devices may be used).
  • Connects to the V1000 via RS-485.
  • Receives and processes real time commands from the V1000.
  • Reports all activity to the V1000.
  • Allows complex input/output linking when used with the V1000 and V300 Output Control Interface.
  • Attractive polycarbonate enclosure protects components from damage.
  • All connections and indicators are fully identified by silk-screened nomenclature on the cover.
  • UL 294 and UL 1076 recognized components.

Dimensions: 5.8" W x 4.825" H x 1.275" D (147.32 mm x 122.55 mm x 32.38 mm)

Weight: 12.4 oz (.35 kg)

Power Supply Requirements: 50 mA @ 9-18 VDCRecommended: Supervised linear power supply with battery back-up, input surge protection, and AC fail and battery low contact outputs. Separate supervised DC supply with battery back-up recommended for relay activated devices.

Cable Distance:

  • RS-485 - 4000 feet (1220 m) to host, using Belden 3105A,22AWG twisted pair, shielded 100? cable Input Circuits - 500 feet (150 m), two-conductor, shielded,using ALPHA 1292C (22AWG) or Alpha 2421C (18AWG).
  • Output Circuits - 500 feet (150 m), 2-conductor, using ALPHA. 1172C (22AWG) or Alpha 1897C (18AWG). Minimum wire gauge depends on cable length and current requirements.

Certifications:

  • UL 294 and UL 1076 Recognized Component for the US
  • CSA 205 for Canada
  • FCC Class A Verification
  • EMC for Canada, EU (CE Mark), Australia (C-Tick Mark), New Zealand, Japan